home home
Search:


MIL-PRF-55110F

This specification establishes the qualification and performance requirements for rigid single -sided printed wiring boards, rigid double-sided printed wiring boards, and rigid multilayer printed wiring boards with plated through holes
Printed wiring boards shall be of the types shown
  • Type 1 - Single-sided board.

  • Type 2 - Double-sided board.

  • Type 3 - Multilayer board.

 

Mil-Certifications
MIL-SPEC
Type Etch Back
MIL-PRF-55110 1,2,3 Single, Double and multilayer (epoxy & Polyimide) x
MIL-P-50884 1,2,3,4,5 Single, Double & multilayer (flex & rigid flex) x
MIL-I-45208 Inspection System  
ISO-9002 Certified November 28, 1999

 

 
 

Home > Company Overview >

In addition to building to IPC Class 2 AND Class 3 standards, Pioneer maintains Mil (DSCC) certifications to the Mil-P-50884 and Mil-PRF-55110 specifications.

Mil-P-50884

This specification establishes the requirements for flexible printed-wiring (with or without shield (s) or stiffeners) and rigid and flexible printed-wiring combinations. The rigid and flexible printed-wiring combination is called a rigid-flex printed wiring board. In the rigid-flex application, the conductor layers that are in the flexible portion are also a layer in the rigid multilayer board.

The flexible and rigid-flex printed-wiring covered by this specification are organized in the following types and classes.

Types:

  • Type 1 - Singled-sided flexible material with or without shield (s) or stiffener (one conductor layer).

  • Type 2 - Double-sided flexible material with or without shield (s) or stiffener (two conductor layers) with plated-through holes.

  • Type 3 - Multilayer flexible material with or without shield (s) or stiffener (more than two conductor layers) with plated-through holes.

  • Type 4 - Multilayer rigid and flexible material combinations (more than two conductor layers), with plated-through holes.

  • Type 5 - Bonded rigid and/or flexible material combinations (more than one conductive layer) without plated-through holes.

Classes:

  • Class A - Capable of withstanding flexing during installation.

  • Class B - Capable of withstanding continuous flexing for a number of cycles specified on the master drawing. (Generally not used for more than two conductor layers).

 

CONTACT US  


Contact Us for more information or to discuss your specific project.


 

Copyright © 2002. Pioneer Circuits, Inc.

top visitors contact end use applications tech domain products and services company overview home